Přejít na obsah
Ceiling Fan Switch 3 Speed 4 Wire Zing Ear ZE 268S6 Pull Chain Switch Control Replacement 3 Speed Control S Witch Ceiling Fans, Wall Lamps, Cabinet Light

Price:

$ 12,91


Ceiling Fan Switch 3 Speed 4 Wire Zing Ear ZE 268S6 Pull Chain Switch Control Replacement 3 Speed Control S Witch Ceiling Fans, Wall Lamps, Cabinet Light

https://m.media-amazon.com/images/I/61akbRjoKbL.jpg
15 sold in last 24 hours
  • Stainless Steel
  • Zing Ear Ceiling Fan Switch 3 speed 4 wire pull chain replacment: Model ZE-268S6.
  • 3 Speed control: high, medium, low ; Function: off, L-1, L-2-3, L-3
  • Ceiling Fan Parts Certifications: UL approved (USA) - CSA certified (Canada).
  • ZE-268S6 Ceiling Fan Switch Electrical Rating: 6A/125VAC - 3A/250VAC.
  • Perfect for home applications such as Ceiling Fans, Wall Lamps, Cabinet Light. Works in Hunter, Casablanca, Harbor Breeze, Hampton Bay and so on

$ 12,91 12.91 USD $ 12,91

Not Available For Sale

($ 12,91 / Units)
10 people are viewing this right now

  • Výrobce
  • Počet jednotek
  • Rozměry prvku L x W x H
  • Kontrolní metoda
  • PŘÍLOHA
  • Typ regulátoru
  • Kontaktní materiál
  • Typ kontaktu
  • Aktuální hodnocení
  • Provozní napětí
  • Terminál
  • Typ obvodu
  • Typ akumulátoru
  • Značka
  • UPC
  • Typ ovládání
  • Počet položek
  • Režim provozu
  • Kompatibilní zařízení
  • Příkon
  • Materiál
  • Barva
  • Typ konektoru
  • Typ montáže
  • Hmotnost položky
  • Typ přepínače
  • Číslo části
  • Model
  • Typ materiálu
  • Mezinárodní hodnocení ochrany
  • Počet pozic
  • Protokol o propojení
  • Rozměry položky
  • Typ výrobku

Tato kombinace neexistuje.

Tažný řetěz

Obchodní podmínky
30denní záruka vrácení peněz
Doprava: 2-3 pracovní dny

Estimated shipping
Select a product to estimate shipping.

Important information

Please disconnect the power to the fan before removing the old switch.

This 3-speed 4 wire fan switch fits many ceiling fans including Hunter, Harbor Breeze, Hampton Bay, Casablanca, Westinghouse, Emerson, and Kichler.

Attention: Before rewiring any ceiling fan. Turn off electrical current at source by turning off circuit breakers.

Steps:

1. Write down the color of each wire and the portal number to which they are attached on the switch

2. Remove wires from the existing fan switch If wires are hard to remove, insert a paper clip or a large sewing needle into each hole (numbered 1, 2, 3, L)and pull the wire out (repeat this step for each wire)

3. Make sure that the Wire lead length is the same length as the line beside the word "STRIP"

4. Insert wires into the new switch as in the previous switch(see step 1) Wires should be inserted into the slots on side of the switch not the holes on the surface

Color Codes For Ceiling Fans( Your Fan Wires Color &Position May Vary)

Harbor Breeze ceiling fan: L=Black, 2=Brown, 1=Gray, 3=Purple OR L=Black, 2=Gray, 1=Brown, 3=Purple

Harbor Breeze ceiling fan-alternate colors: L=Black, 2=Pink, 1=Yellow, 3=Gray

Hampton Bay ceiling fan: L=Black, 2=Brown, 1=Purple, 3=Gray OR L=Black, 2=Brown, 1=Gray, 3=Purple

Hampton Bay ceiling fan -Alternate colors: L=Black, 2=Purple, 1=Red, 3=Yellow

Hunter ceiling fan: L=Black, 2=Brown, 1=Gray, 3=Green

Monte Carlo ceiling fan: L=Back, 2=Brown, 1=White, 3=Purple

What situation you should replace your ceiling fan pull switch?

A. Your ceiling fan pull switch doesn't work

B. Internal ceiling fan chain break.

When no ceiling fan chain is visible, this likely means that the pull within the ceiling fan has broken near or inside the ceiling fan pull switch. In that case, proceed to replace.

Equipment & Tools

6-foot step ladder

Voltage tester

Wire stripper

Manual screwdriver

Pliers (if needed)

Soft rag (if needed)

Pull chain extender or pull chain switch kit

Electrical wire nuts

Remove the Metal Collar

Unscrew the metal collar through which the ceiling fan chain should extend. First try screwing off the collar with your fingers, turning counterclockwise. If this does not work, use pliers and a soft rag wrapped around the metal collar to protect the collar and the fan housing from damage.

Open the Fan Base

Remove any light bulbs from the ceiling fan. With a manual screwdriver, turn out the screws holding the removable lower section from the ceiling fan motor base. Set the screws aside. Gently pull off the removable section. Leave it attached by its wires to the ceiling fan base.

Pull out the Pull Chain Switch

Locate the ceiling fan chain switch. It should be a small plastic unit, often with a transparent side or green one. You may even be able to see the broken pull within the switch unit. Carefully pull this down. It will be usually attached to the fan with three or four wires.

WARNING: Do not attempt to fix the pull chain switch. Instead, it is easier and safer to discard the old switch and replace it with a new switch. Ceiling fan pull switch kits are inexpensive and readily available online.

Cut the Wires to the Fan Chain Switch

With the wire stripper, use the cutting section to snip off the three or four wires that attach the ceiling fan chain switch to the ceiling fan base. Leave at least 2 inches of wire attached to the ceiling fan base to make it easier to reattach the new pull chain switch.

Attach the New Pull Switch to the Ceiling Fan

After stripping the plastic from the wires to expose the copper wire, attach the three or four wires of the new ceiling fan chain pull switch to the fan's wires. Twist together the wires. Top off each connection with a plastic wire nut.

Tips: Be very careful to match the wiring of the old switch with the wiring of the new switch.

Thread the Pull Chain Through the Hole

Gently press the pull chain switch back into the ceiling fan base. Thread the pull chain through the hole in the housing.

Reassemble and Test the Ceiling Fan

Tighten the metal collar by hand. Reattach the lower section of the ceiling fan. Add any light bulbs. Turn the power back on at the circuit breaker and any wall switches. Test the fan by carefully pulling on the ceiling fan pull.

Product details

Ceiling Fan Pull Chain Switch - 3 Speed Replacement -14
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -15
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -16
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -17
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -18
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -19
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -20
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -21
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -22
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -23
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -24
Main Specification
PŘÍLOHA CSA or Ul_listed
Kompatibilní zařízení Ceiling Fans or Wall Lamps or Cabinet Lights or Hunter or Casablanca or Harbor Breeze or Hampton Bay
Výrobce DAYONE
Počet jednotek 1 Počet
Rozměry prvku L x W x H 1.97 x 1.18 x 0.59 inches
Kontrolní metoda Aplikace
Typ regulátoru Manual Pull Chain
Kontaktní materiál Nickel
Typ kontaktu Make
Aktuální hodnocení 6 A
Provozní napětí 250 voltů
Terminál Přes díru
Typ obvodu 3- way
Typ akumulátoru Rotary
Značka DAYONE
UPC 703064554037
Typ ovládání Speed Control
Počet položek 1
Režim provozu Vypnout
Příkon 750 W
Materiál Plastové
Barva ZE-268S6 Nickel 1Pack
Typ konektoru Crimp
Typ montáže Vložené
Hmotnost položky 8 g
Product information
Typ přepínače Pull Chain Speed Switch
Technical Details
Číslo části ZEAM2800
Model ZEAM2800
Typ materiálu Plastové
Mezinárodní hodnocení ochrany 125
Počet pozic 4
Protokol o propojení Electrical Wire
Measurements
Rozměry položky 1.97 x 1.18 x 0.59 inches
Others
Typ výrobku Zatáhnout řetězy